Survey recommendations

There is oil and water in the bilge. The bilge must be cleaned of any oil before operating the bilge pump, and the pump tested before the vessel is placed in operation.

110V receptacles must be upgraded to GFCI

Propane tanks must be stowed in a dedicated locker, with the tank rigidly secured against movement, and/or where any vapors escaping the tank will drain overboard and not into any enclosed spaces on the vessel.

Safety signs must be installed at gas appliance and/or at propane tank.

The stern and anchor light (clear) lenses are faded and frosted. Replace.

The following through-hull valves are frozen (immobile) and must be repaired: (3) cockpit drain/bilge discharges in port lazarette and (1) in aft lazarette.

Some identified switches should be labeled at the electrical panel and throughout vessel.

Replace wire nuts with marine grade butt connectors.

Batteries must be secured and/or contained in a liquid-tight, acid-proof container. Batteries and battery installation is in poor condition and system needs to be inspected, repaired &/or renewed by a certified marine electrician. Batteries appear to be overcharging and venting out excessive amounts of battery acid. Bus bars have excessive wires & cables connected to terminal posts and most all of the connections are corroded.

The liferaft was last serviced in 6 / 04. 3-year service is required.

A yellow 12V wire behind the navigation equipment electrical panel is connected to bus bar, but loose on other end. Remove wire.

110V wiring of this vessel consists of yellow, white and green wires. Extreme caution must be exercised to ensure yellow “hot” wire of 110V system is not confused with the yellow 12V “negative” wires. Where possible, it is strongly recommended to replace original 110V wiring with approved marine grade wiring with proper color schedule as per ABYC E-11 specifications.

The back of the AC panel is not covered. Install plastic cover to protect against possible electrocution as per ABYC E-11.14.6 recommendations.

Lanyard attaching the water light to the horseshoe buoy is wasted and requires replacement.

Vinyl tubing used on fuel tank vent system is not to code. Replace existing hose with USCG approved type A-1 fuel hose.

Engine blower ducting is crushed and severed under port quarter berth. Repair.

Handle for engine seacock valve is missing securing nut and handle tends to fall off into bilge. Replace securing nut.

High-level bilge pump discharge hose is badly kinked and restricts water flow.
Intake hose for manual bilge pump lies unsecured in bilge and lack’s the required strainer or screen. Repair.

Man overboard pole is resin deficient. Coating of resin is needed to strengthen fiberglass pole and protect against skin irritation if/when touched.